How are bioequivalence acceptance limits widened for highly variable drugs?
Bioequivalence & biowaivers · Highly variable drugs (Widened / scaled Cmax limits). Verbatim excerpts from each authority's document, with the section.
SFDA Saudi Food and Drug Authority
SFDA Guidelines for Bioequivalence v3.1 (DS-G-010)
Highly variable drug products (HVDP) are those whose intra-subject variability for a parameter is larger than 30%. If an applicant suspects that a drug product can be considered as highly variable in its rate and/or extent of absorption, a replicate cross-over design study can be carried out.SFDA BE v3.1 · 3.1.10 Highly variable drugs or drug products ↗
Those HVDP for which a wider difference in Cmax is considered clinically irrelevant based on a sound clinical justification can be assessed with a widened acceptance range. If this is the case the acceptance criteria for Cmax can be widened to a maximum of 69.84 – 143.19%. For the acceptance interval to be widened the bioequivalence study must be of a replicate design where it has been demonstrated that the within-subject variability for Cmax of the reference compound in the study is >30%.SFDA BE v3.1 · 3.1.10 Highly variable drugs or drug products ↗
The geometric mean ratio (GMR) should lie within the conventional acceptance range 80.00-125.00%. The possibility to widen the acceptance criteria based on high intra-subject variability does not apply to AUC where the acceptance range should remain at 80.00 – 125.00% regardless of variability.SFDA BE v3.1 · 3.1.10 Highly variable drugs or drug products ↗
EU European Union
ICH M13A · ICH M9 · EMA BE guideline
Those HVDP for which a wider difference in Cmax is considered clinically irrelevant based on a sound clinical justification can be assessed with a widened acceptance range. If this is the case the acceptance criteria for Cmax can be widened to a maximum of 69.84 – 143.19%. For the acceptance interval to be widened the bioequivalence study must be of a replicate design where it has been demonstrated that the within-subject variability for Cmax of the reference compound in the study is >30%.EMA BE guideline · 4.1.10 ↗
The geometric mean ratio (GMR) should lie within the conventional acceptance range 80.00-125.00%. The possibility to widen the acceptance criteria based on high intra-subject variability does not apply to AUC where the acceptance range should remain at 80.00 – 125.00% regardless of variability.EMA BE guideline · 4.1.10 ↗
It is, therefore, highlighted that the requirements of both ICH M13A and the existing EMA Guideline read in conjunction may be applicable to e.g., • BE studies with highly variable drugs (replicate design) • drugs with narrow therapeutic index, and • complex BE study designs and data analysis e.g., • adaptive design.EMA M13A implementation · Implementation ↗
US FDA US Food and Drug Administration
M13A · M9 · ANDA BE · statistics · 21 CFR 320
Highly variable drugs are drugs for which within subject variability (%CV) in BE measures 30 percent or greater and that are not considered NTI drugs. In order to use the reference-scaled average BE approach for highly variable drugs, a partial or fully replicate crossover design should be used. The statistical analysis should be carried out using the mixed scaling approach below for both AUC and Cmax.FDA Statistical Approaches 2026 · III.C ↗
If the estimated within-subject standard deviation of the reference is < 0.294, the average BE two one-sided test procedure should be used to determine BE for the individual PK parameter. Otherwise, the reference-scaled average BE procedure should be used to determine BE for the individual PK parameter together with a point estimate constraint for the estimated test/reference geometric mean ratio, which should be bounded by 80.00 percent to 125.00 percent.FDA Statistical Approaches 2026 · III.C ↗
A replicate design is advantageous over a nonreplicate design for non-narrow therapeutic index (NTI) drugs with a high intrasubject variability. Either a partial or fully replicate design may be used, but a reference-scaled BE analysis approach should only be applied to specific PK metrics that exhibit a high within-subject variability for the reference standard in the pivotal BE study.FDA ANDA BE 2026 · III.A.4 ↗
WHO World Health Organization
TRS 1052 Annex 8 (2024)
A “highly variable API” has been defined as an API with an intrasubject variability of > 30% in terms of the ANOVA coefficient of variation (CV) (14).WHO TRS 1052 Annex 8 · 7.9.3 ↗
For highly variable FPPs it is recommended that a three-way partial replicate (where the comparator product is administered twice) or a four-way fully replicated crossover bioequivalence study be conducted and reference-scaled average bioequivalence be employed to widen the acceptance interval for the Cmax parameter, if the intrasubject variability for Cmax following replicate administrations of the comparator product is > 30%. If this is the case, the acceptance criteria for Cmax can be widened to a maximum of 69.84–143.19%.WHO TRS 1052 Annex 8 · 7.9.3 ↗
The geometric mean ratio for Cmax should lie within the conventional acceptance range of 80.00–125.00%. The standard bioequivalence acceptance criterion for AUC should be maintained without scaling.WHO TRS 1052 Annex 8 · 7.9.3 ↗
Other questions in Bioequivalence & biowaivers
- When is an in vivo bioequivalence study required?
- What is the standard bioequivalence study design?
- How many subjects, and which population, are required in a bioequivalence study?
- When are fasting and fed bioequivalence studies required?
- Which reference (comparator) product must be used in a bioequivalence study?
- Which strength must be tested in a bioequivalence study?
- What should be measured in a bioequivalence study: parent drug, metabolite or enantiomers?
- What are the bioequivalence acceptance limits for AUC and Cmax (90% confidence interval)?
- What bioequivalence acceptance limits apply to narrow therapeutic index drugs?
- When can additional strengths be waived from bioequivalence testing?
- When is a BCS-based biowaiver accepted?
- How is dissolution profile similarity (f2) assessed?
Excerpts are selected for comparison and are not the whole requirement; the binding text is each authority's current official document. Not regulatory advice.